Summit Instrument

Scales SEC without limits

EV isolation and concentration for high-throughput labs. The Summit is a fully autonomous, plate-based platform that isolates EVs from up to 48 samples in parallel, from column preparation to recovery, with no user intervention.

  • Process 4–48 samples per run, fully automated
  • Plate-based SEC or standard Apex columns
  • On-deck plate-based ultrafiltration to concentrate fractions
  • Built for biobanks, CROs and 1,000+ sample studies
Summit high-throughput automated EV isolation instrument

4–48

Samples per run

1–3 hr

Typical isolation time

10X

On-deck concentration

Walk away

Fully automated

How it works

Load, press run, walk away

The Summit runs the entire plate-based SEC workflow, column preparation, isolation and recovery, without intervention. A typical isolation takes 1–3 hours.

1

Load samples

Load 4 to 48 samples onto the deck and choose your isolation parameters, fractions, volumes and concentration.

2

Press run

The Summit prepares the SEC plate and isolates every sample autonomously, with no user intervention.

3

Collect

Recover isolated EVs in a deep-well plate or low-bind tubes, optionally concentrated on-deck and ready for analysis.

Flexible SEC formats

Run Apex plates or columns

Use plate-based SEC for maximum throughput, or run the same Apex columns you validated on the Ascent, both deliver equivalent, reproducible separation.

24-well SEC plates

Available in Apex 4B and 6B. Each well is an individual SEC column with the same resin and bed volume as an Apex column: equivalent performance, scaled across the plate.

Apex columns

Run Apex MM, 4B and 6B columns directly on the Summit via the column adapter: ideal when you are running a few samples.

Reproducible across 48 samples

EV particle concentration across two plates with CV 4.4 percent and 5.3 percent within plates and 1 percent plate to plate
Within-plate CV ≈ 5% (4.4% and 5.3%) and just 1% plate-to-plate in EV recovery.

Plates match columns

EV elution profiles for Apex columns on the Ascent and Apex SEC plates on the Summit overlap across fractions 1 to 3
EV elution from Apex columns (Ascent) and Apex SEC plates (Summit) overlaps across fractions: equivalent separation in either format.

Integrated concentration

Concentrate EVs on-deck with Altitude plates

Collect SEC fractions directly into Altitude ultrafiltration plates during the run. On-deck ultrafiltration concentrates EVs in a 24-well format: balancing high recovery with volume reduction, all without a separate spin-down step.

  • Direct collection of fractions into UF plates during the run
  • Reduce volume down to ~100 µL for concentrated isolates
Everest Altitude Concentration Plate — 24-well ultrafiltration plate

~10X concentration

EV particle concentration before versus after on-deck Altitude ultrafiltration, about a 10X increase
EV particle concentration before vs after on-deck ultrafiltration, 75–90% EV recovery, down to ~100 µL.

Engineered for scalable, reproducible studies

Fully autonomous

Runs the entire workflow, column preparation through EV recovery, without user intervention.

Plate-based SEC

A 24-well plate format where each resin-packed well functions as an individual SEC column.

Apex-equivalent separation

The SEC plate uses the same resin and bed volume as Apex columns, so separation matches the column format.

On-deck concentration

Altitude ultrafiltration plates concentrate fractions on the instrument: up to ~10X, no separate spin-down step.

Built for scale

Ideal for biomarker discovery and validation, including clinical studies for formulation development, across large cohorts, biobanks and CROs, up to 1,000+ samples.

Configurable runs

Collect 1–3 fractions and set fraction volumes from 0.5 to 2.0 mL to maximize EV yield.

Compare instruments

Summit or Ascent?

The Summit is built for large cohorts and integrated concentration. For flexible, column-based prep at 1–8 samples, the Ascent is the right fit.

SummitAscent
Best forLarge cohorts & standardized workflowsFlexible sample prep
Throughput focusHighModerate
SEC formatPlates or columnsColumns
Sample capacity4–481–8
Automation levelFully automatedManual sample loading
Fraction collection1–3 per sample1–12 per sample
ConcentrationIntegrated capabilityPerformed externally
FootprintLarger, built for scaleCompact benchtop

One workflow

From discovery to clinical scale

Start on the Ascent for flexible 1–8 sample runs, scale to the Summit for 48-sample studies, and quantify every fraction with the Atlas EV ELISA: one reproducible, end-to-end workflow.

Technical information

Summit specifications

SpecificationSummit
Samples per run4–48
SEC compatibilityApex 4B & 6B (plates or columns); Apex MM (columns)
SEC plate format24-well: each well is an individual SEC column
UltrafiltrationAltitude UF plate (on-deck concentration)
Fractions1–3 (up to 24 samples); 1 per sample (48 samples)
Fraction volume0.5–2.0 mL, configurable
Input / output format2.0 mL deep-well plate or 2.0 mL low-bind tubes
Pipette tipsLiHa P1000 tips
Bottle capacity4 L (1 US gallon)
VacuumInternal instrument vacuum or house vacuum
Dimensions (W×D×H)93 × 65 × 76 cm (37 × 26 × 30 in)
Input power100–240 VAC (50–60 Hz)
Power supply unit24 Vdc, 5 A, 120 W
ConnectivityUSB 3.1 (for software updates)
Operating conditions10–24 °C, 30–80% RH
Chemical compatibilityPBS, DI water, 70% ethanol, dilute sodium hypochlorite, sodium hydroxide (NaOH)

FAQ

Frequently asked questions

How many samples can the Summit process?

The Summit processes 4 to 48 samples per run, fully automated. Just load your samples, choose your parameters, and press run.

Can I use Apex columns, or only plates?

Both. Run 24-well Apex SEC plates (4B and 6B) for throughput, or run Apex MM, 4B and 6B columns via the column adapter. The plate uses the same resin and bed volume as the columns, so separation is equivalent.

How long does a run take?

A typical isolation takes 1–3 hours. The exact time depends on how many samples you run, the biofluid type, and whether you concentrate the fractions.

How many fractions does it collect?

It collects 1–3 fractions when processing up to 24 samples, and 1 fraction per sample at 48 samples. Fraction volume is configurable from 0.5 to 2.0 mL.

Can it concentrate my samples?

Yes. SEC fractions are collected directly into Altitude ultrafiltration plates during the run, concentrating EVs up to ~10X (down to ~100 µL) with 75–90% recovery: no separate spin-down step.

Can I transfer a protocol from the Ascent?

Yes. Parameters transfer directly, and because the SEC plate uses the same resin and bed volume as Apex columns, the elution profile matches what you validated on the Ascent.

Contact us

Scale your EV studies

Tell us about your cohort size and sample types, and our team will help you plan a high-throughput Summit workflow and arrange a virtual demo.