Applications
Lipid nanoparticle purification and screening
Targeted LNPs need cleanup before they can be screened. Apex SEC columns gently remove free targeting ligand while preserving particle size and encapsulation, and the Ascent and Summit scale that cleanup from one formulation to 48.
- >99% of free targeting ligand removed
- Particle size and encapsulation preserved
- 8 formulations in parallel on the Ascent
- 48 formulations purified and concentrated on the Summit

>99%
Free ligand removed
86%
tLNP RNA recovery
Unchanged
DLS size distribution
6.3×
On-deck concentration
The challenge
Targeted LNPs require cleanup
Surface ligands such as antibodies, peptides, aptamers, and sugars steer LNPs to specific cell types, extending mRNA delivery beyond the liver. Conjugating the ligand after the LNP is formed gives greater flexibility in chemistry and ligand options, but excess ligand remains in solution and must be removed before analysis and testing.
Screening is a numbers game
- Vary lipid ratios, ligands, and ligand densities across dozens of formulations
- Every formulation needs clean, reproducible purification before testing
- Manual cleanup can’t keep up with screening throughput
Why SEC
The field-standard cleanup, prepacked and lot-validated
Gravity SEC on cross-linked agarose is the accepted way to remove unbound ligand from targeted LNPs. tLNPs (~100–200 nm) are excluded from the resin pores and elute early, while free ligands enter the pores and elute later. No pressure, shear, or high g-force is applied, so particle size and integrity are preserved. Apex 4B columns and 24-well plates run that same CL-4B separation in a prepacked, lot-validated format.
>85%
tLNP recovery on Apex 4B
In an antibody-spiking study, Apex 4B removed more than 99% of free anti-CD3 IgG, recovered 86% of tLNP RNA, and left the DLS size distribution unchanged. The same cleanup prepares labeled LNPs for single-particle analysis by nano-flow cytometry, where unbound label would otherwise raise background and create false positive events.
Scale
Choose your scale
From your first conjugation to a full formulation screen: the same Apex separation, at three levels of automation.
| Manual Apex columnLearn more → | AscentLearn more → | SummitLearn more → | |
|---|---|---|---|
| Formulations per run | 1 per user | 8 | 4–48 |
| Hands-on time per run | ~70 min | ~5 min | ~10 min |
| SEC format | Apex column | Apex or third-party columns | Apex 24-well SEC plate |
| Fully automatic wash | No | Yes | Yes |
| ColumnSaver | No | Yes | Yes |
| Concentration | Manual, off-line | Centrifugal concentrators | Fully automated, on deck |
| Sample input / output | Tubes | Tubes | Tubes or 96-well plate |
Automate
Ascent: 8 formulations in parallel
Program the run on the touchscreen: column type, wash and discard volumes, number and volume of fractions. Load your samples and walk away; about an hour later, 8 formulations are purified with no hands-on time after loading.
- Run or wash up to 8 columns side by side
- Compatible with Apex, third-party, and home-packed columns
- Up to 12 fractions per column with programmable sequences
- Collect tLNP fractions directly into centrifugal concentrators for low-volume assays

Scale up
Summit: purify and concentrate 48 formulations at once
The Summit runs Apex 24-well SEC plates, so conditions you develop on columns transfer directly. Every formulation is washed, purified, and concentrated on deck in a single unattended run, delivered to tubes or a 96-well plate, ready for screening.
SEC dilutes your sample; the Summit gives the concentration back. An ultrasonic sensor measures volume, so you choose the final output volume. In head-to-head runs the Summit concentrated pooled SEC eluate 6.3-fold with 75% RNA recovery, matching manual centrifugal filters while running unattended and with tighter run-to-run spread, and DLS size distributions overlay before and after.

Contact us
Plan your LNP cleanup workflow
Tell us about your formulations, ligands, and screening scale, and our scientists will help you match the right columns and automation to your workflow.