Applications

Extracellular vesicle isolation and analysis

A complete EV workflow built around gentle size-exclusion chromatography: isolate intact, functional vesicles, automate the separation, and quantify yield and purity, all on one platform.

  • High-yield, high-purity EV isolation from any biofluid
  • Automate 8 columns or 48 samples per run
  • EV-specific quantification with Atlas ELISA
  • Validated in cell culture, plasma, serum, urine & CSF
Extracellular vesicle isolation with Apex SEC columns

>90%

EV yield

>99.9%

Albumin depletion

<10%

CV in EV yield

48

Samples per automated run

Why SEC

Gentle, size-based isolation

Ultracentrifugation and precipitation force a trade between yield, purity, and vesicle integrity. Size-exclusion chromatography avoids the trade-off: EVs are excluded from the resin pores and elute first, while free proteins enter the pores and elute later. No pressure, shear, or high g-force is applied, so vesicles stay intact and functional.

SEC working principle diagram
Size-exclusion separation principle. EVs are excluded from the resin pores and elute first (Fractions 1–3), while smaller contaminating proteins enter the pores and elute later (Fractions 4+). Apex columns are optimized so EVs reproducibly elute in Fractions 1–3, giving you a predictable collection window.

Isolate

Choose the Apex column matched to your biofluid

Every Apex column runs the same gentle SEC separation; the resin sets the yield-versus-purity balance. Pick by sample type, then scale from a single column to a 24-well plate without changing the separation.

Apex MM

Peak purity

Peak depletion of lipoproteins for plasma and serum.

Apex 4B

High purity

High purity for complex biofluids, free of secreted proteins.

Apex 6B

Highest yield

Recover the most vesicles from low-complexity samples.

Automate

Ascent: hands-free isolation, 8 columns at a time

Load your samples, press run, and walk away. The Ascent runs up to 8 SEC columns in parallel with programmable fraction collection, so reproducible EV fractions are ready in about an hour.

  • 1–8 columns in parallel, up to 12 fractions each
  • Programmable sequences for any column type
  • Open platform: Apex, third-party and home-packed columns
  • ColumnSaver keeps idle columns hydrated
Ascent automated EV isolation instrument with Apex columns
The Ascent instrument with Apex columns loaded.

Scale up

Summit: up to 48 samples per unattended run

The Summit runs Apex 24-well SEC plates and columns, purifying up to 48 samples in a single automated run with on-deck concentration. Plate-based SEC performs equivalently to column-based SEC, so conditions you develop on a column transfer directly.

Summit instrument for plate-based automated SEC
The Summit instrument: plate-based SEC with automated concentration.

Quantify

Measure EV yield with Atlas ELISA

Atlas EV ELISA kits detect intact vesicles with a 3-in-1 pan-tetraspanin capture, so you can track EV yield across every fraction and every run. Available in absorbance and chemiluminescent formats, plus a Homebrew kit for your own markers.

Atlas EV ELISA kit
Atlas EV ELISA: EV-specific measurement of yield.

Intact & functional EVs

SEC isolates vesicles gently, preserving their structure and biological activity. Vesicle morphology is confirmed by transmission electron microscopy, and SEC-isolated EVs underpin a growing body of peer-reviewed work.

Peer-reviewed evidence

Each study below isolated EVs by size-exclusion chromatography: confirming that gently isolated vesicles stay intact and biologically active.

Contact us

Plan your EV workflow

Tell us about your biofluid and downstream assay, and our scientists will help you build an EV workflow from isolation to quantification.