Peak EV isolation

Ascent Instrument

  • Run up to 8 columns in parallel
  • Collect up to 12 fractions per column
  • Wash up to 8 columns
  • Compatible with different column types
  • Programmable fraction collection sequences

Programmable fraction collection

You may adjust these values for your application to work with different column types, between 1 and 8 columns, wash volumes, number of fractions to collect, and the fraction volume.

Technical information

It can operate up to 8 columns simultaneously and is compatible with Apex columns as well as other brands. The programmable fraction collection allows you to optimize collection for any application.
SEC column capabilityApex 4B
Apex 6B
Izon qEVoriginal
Izon qEV1
Izon qEVsingle
Dimensions (WxDxH)397mm x 364mm x 331mm
15-5/8” x 14-5/8” x 13”
Weight13.6 Kg / 30.0 lbs.
Input Power100~240 VAC (50-60Hz)
Power Supply Unit24 Vdc, 2.1A, 50W
Environmental Temperature10°C -24°C (50°F-75°F)
Relative Humidity30-80% RH
Bottle Capacity1000mL
ConnectivityUSB-C (for software updates)
Chemical CompatibilityPBS, DI, 70% ethanol, dilute bleach

Frequently Asked Questions

How long does it take to purify samples on the Ascent?

Running 1 or 8 Apex columns takes about an hour. Since columns are run in parallel, it takes about the same time for any number of columns. First, the columns are washed to remove buffer containing antimicrobial agents. This step takes ~45 minutes. Then the fractions are collected. This takes ~5-15 minutes depending on how many fractions are collected. Apex 4B and 6B columns have the same run time.

Can the Ascent run columns from other suppliers?

Yes. In addition to the Apex columns, the Ascent is compatible with qEVoriginal, qEV1, and qEVsingle columns. If you would like support for additional columns, please contact us.

Can the fraction collection sequence on the Ascent be customized?

Yes. The fraction collection sequence on the Ascent is programmable. The user can adjust the discard volume and the fraction volume according to the input sample volume.

What is Column Saver?

Column Saver automatically keeps columns hydrated. This prevents your columns from drying out if you are not near the instrument when the wash or fraction collection completes. The Column Saver slowly drips buffer into the columns while the Ascent waits for an action from the user (adding samples or removing the columns when it completes).

How does the Ascent accurately collect the correct fraction volume?

Ascent Instrument

The Ascent has a high-precision liquid handling system combined with an advanced optical drop detection platform to precisely collect fractions. This approach is robust to vibrations and can be used on any lab bench.